Parameters
Application Scope: Used in well control systems for remotely controlling the opening and closing of blowout preventers (BOPs). It can be directly exposed to flames at 704°C for over 5 minutes, ensuring the control system remains operational in emergencies.
Hose Structure
Inner Rubber Layer: NBR (Nitrile Butadiene Rubber)
Reinforcement Layer: Multi-layer Wrapped High-Strength Ultra-Flexible Steel Wire
Outer Rubber Layer: High-Temperature and Fire-Resistant Synthetic Rubber
Outer Protective Layer: Stainless Steel Armor
Temperature Range: -40°C ~ +100°C (-40°F ~ +212°F)
Fire Resistance: Complies with API Spec. 16D, passing the 704°C x 5-minute fire resistance test without leakage.
Hose Structure
Inner Rubber Layer: NBR (Nitrile Butadiene Rubber)
Reinforcement Layer: Multi-layer Wrapped High-Strength Ultra-Flexible Steel Wire
Outer Rubber Layer: High-Temperature and Fire-Resistant Synthetic Rubber
Outer Protective Layer: Stainless Steel Armor
Temperature Range: -40°C ~ +100°C (-40°F ~ +212°F)
Fire Resistance: Complies with API Spec. 16D, passing the 704°C x 5-minute fire resistance test without leakage.
I.D in | W.P Psi | P.P Psi | Min.B.P Ps | Min.B.R mm | W.T kg/m |
1/2 | 5000 | 7500 | 15000 | 300 | 1.6 |
3/4 | 5000 | 7500 | 15000 | 400 | 2.1 |
1 | 5000 | 7500 | 15000 | 500 | 3.5 |
1 1/2 | 5000 | 7500 | 15000 | 700 | 5.3 |
2 | 5000 | 7500 | 15000 | 800 | 7.4 |